$1.00
Description
LaMotte alkalinity test kits can be used to measure phenolphthalein (P) alkalinity, total (T) alkalinity or both. Each kit uses a different test method and those methods are outlined below. There are 5 kits to choose from (see specifications tab below for detail).
What is a titration?
Titrimetric tests are used to determine the concentration of a substance in a solution. After the sample solution is treated with an indicator, a titrant is gradually added until a colour change indicates a completed reaction. Our kits use a variety of different titration methods, including the direct reading tirator, dropper pipette or dropper bottle method.
Direct reading titrator method
The direct reading titrator is a 1.0 mL microburet calibrated to allow direct reading of the test result. Each titrator has a specific range, but may be refilled to test higher concentrations.
Dropper pipette method
The drop count test uses a pipette to provide fast, reliable measurements in the field. The number of drops used to obtain a colour change is multiplied by a given factor to produce the test result.
Dropper bottle
The dropper bottle test uses bottle tips which deliver a consistent standard drop size to add titrant to the sample. As with the drop count test, the number of drops used to complete the reaction is multiplied by a given equivalence factor to determine the concentration.
Downloads
Specifications
Test | Test method | Range/sensitivity | No. of tests | Test kit order code | Refill order code |
Total alkalinity | Direct reading titrator | 0-200 ppm/4 ppm as CaCO3CaCO3 | 50 at 200 ppm | 4491-DR-01 | R-4491-DR-01 |
P & T alkalinity | Direct reading titrator | 0-200 ppm/4 ppm as CaCO3 | 50 at 200 ppm | 4533-DR-01 | R-4533-DR-01 |
P & T alkalinity | Dropper pipette | 1 drop = 10 ppm as CaCO3 | 50 at 200 ppm | 4533-01 | R-4533 |
P & T alkalinity | Dropper bottle | 1 drop = 10, 25 or 50 ppm as CaCO3 | 100 at 500 ppm | 7240-02 | R-7240-02 |
P & T alkalinity | Direct reading titrator | 0-200 ppm/4 ppm as CaCO3 | 50 at 200 ppm | 3467-01 | R-3467-01 |